Buying guides

New boiler regulations: controls, TRVs and Boiler Plus

When a boiler is replaced, the rules set a minimum efficiency and require proper controls. What that means for your home, how it differs by nation, and what the controls save.

Last reviewed
28 September 2026
7
min read
A hand adjusting a thermostatic radiator valve on a white radiator under a window
Key takeaways
  • A replacement gas boiler must be at least 92% efficient in England, Wales and Scotland.
  • A new combi in England or Wales needs one extra efficiency measure; smart thermostats are one option.
  • In Scotland, that extra measure applies to every boiler replacement, not just combis.
  • Each heated room needs its own temperature control, usually a thermostatic radiator valve.
  • Official measurements show homes fitting a boiler with new controls saved far more gas than a boiler alone.

When a boiler is replaced in Great Britain, the new one must be at least 92% efficient, the system must be cleaned, and the controls must let you set the temperature room by room. A new combi in England or Wales also needs one extra energy-saving measure, and in Scotland that applies to every boiler replacement.

These rules sit in the building regulations guidance for each nation. Your Gas Safe engineer applies them, but knowing them helps you check a quote. For what a new boiler costs, see boiler costs.

What is Boiler Plus?

Boiler Plus was the name the government gave in 2018 to a package of rules for new boilers in England. The rules now sit in Approved Document L, the building regulations guidance on energy, which was updated in 2021 and again in 2023.

People still use the name, and many quotes still mention it. What matters is what the current guidance asks for, which the rest of this guide sets out.

How efficient must a new boiler be?

A new gas boiler fitted in England, Wales or Scotland must be at least 92% efficient on the ErP scale used for today's energy labels. In Northern Ireland the minimum is 88% for gas, oil and LPG boilers, measured on an older scale, and 86% for an oil combi.

Check the efficiency figure for the exact model you are quoted, not just its label: the ErP A band starts at 90%, so an A label alone does not prove a boiler reaches 92%. Our guide to when to replace your boiler explains what the labels mean.

Which controls must be fitted?

For most replacement boilers in England, Approved Document L expects:

  • a timer or programmer, with separate time control for heating and hot water where there is a hot water cylinder;
  • a room thermostat or similar, so the boiler switches off when the home is warm enough, known as boiler interlock;
  • temperature control in each heated room, usually thermostatic radiator valves, often called TRVs;
  • a cleaned and flushed system, with a corrosion inhibitor added, to the British Standard BS 7593.

A TRV should not go on the radiator in the room with the main room thermostat, because the two would fight each other.

What extra measure does a combi need?

In England and Wales, a new combi boiler must come with at least one of four extra energy-saving measures:

  1. Weather compensation: the boiler reads the outdoor temperature and lowers the water temperature on milder days.
  2. Load compensation: it lowers the water temperature as the home nears the set temperature.
  3. Flue gas heat recovery: a unit recovers heat from the flue to warm incoming water.
  4. A smart thermostat with automation and optimisation: it learns how quickly your home heats up and adjusts itself.

So a smart thermostat is one route, not a legal must. Weather or load compensation suits a condensing boiler well, because lower water temperatures let it condense more of the time. In Scotland, one of these measures is expected with every boiler replacement, not just combis.

boilers-replacement-rules-by-nation

The rules change again soon. England's new edition of Approved Document L applies from 24 March 2027 and Wales's from 4 March 2027, keeping the same core requirements for replacement boilers.

What do the controls save?

Official measurements suggest the controls do much of the work. DESNZ compared real gas use in England and Wales before and after measures fitted in 2023:

  • homes that fitted a new condensing boiler saved a median 2.3% of their gas, about 236 kWh a year;
  • homes that fitted a condensing boiler and new heating controls together saved a median 11.5%, about 1,218 kWh.

These are different groups of homes, so the gap is not all down to the controls, but it points the same way as the Energy Saving Trust's estimates.

A worked example: adding controls to an old system

The Energy Saving Trust estimates that fitting a programmer, a room thermostat and TRVs to a home with no controls costs about Β£600 and saves about Β£100 a year in Great Britain, or Β£110 in Northern Ireland.

  • Payback: Β£600 Γ· Β£100 = 6 years in Great Britain, or about 5.5 years in Northern Ireland.
  • Turning the thermostat down one degree, from 22Β°C to 21Β°C, saves about Β£120 a year in Great Britain, according to the same source.
  • VAT: controls fitted on their own carry 0% VAT until 31 March 2027. Fitted as part of a new boiler installation, HMRC treats the whole job as one supply at 20%.

So if your boiler is sound but your controls are basic, upgrading the controls alone can be a cheap first step.

Questions to ask your engineer

  • Which efficiency will the new boiler reach, and can I see its model on the government database?
  • Which extra measure will a combi come with, and why that one?
  • Will every heated room have its own temperature control?
  • How will you clean and flush the system, and which inhibitor will you add?
  • Will you set the boiler's flow temperature to suit my radiators, rather than leaving the factory setting?
  • Will the job be registered with building control, and when will I get the certificate?

Watch out for these

  • "A smart thermostat is mandatory." It is one of four options, and only for combis in England and Wales.
  • Controls left out of the quote. Controls and system cleaning are part of fitting a boiler properly. Ask for them to be listed.
  • Controls fitted but not set up. A thermostat left on factory settings, or TRVs all turned to maximum, saves nothing. Ask the engineer to show you how to use them.
  • Unregistered engineers. Only Gas Safe registered engineers may fit gas boilers; check the ID card.

How the rules differ across the UK

  • England and Wales: 92% minimum efficiency; room-by-room temperature control; an extra measure for combis. Each nation has its own Approved Document L, with new editions due in March 2027.
  • Scotland: 92% minimum; TRVs in all rooms; an extra measure with any boiler replacement, set out in the Domestic Building Services Compliance Guide.
  • Northern Ireland: 88% minimum for gas, oil and LPG boilers. Technical Booklet F1 does not include the combi extra-measure rule; ask your engineer or council building control about controls.
  • Oil and solid fuel: OFTEC-registered engineers fit oil boilers and HETAS-registered engineers fit solid fuel appliances, with their own efficiency rules.

Where to go next

Get a boiler fitted to today's rules

Tell us about your home to get a free, no-obligation quote from a Gas Safe registered engineer, with the controls and system cleaning your nation's rules require included in the price you are quoted.

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.
Compare free quotes

Free and no obligation. We only share your details with the installers we match you with.

Common questions

Does a replacement boiler need building regulations approval?

Yes, but you do not usually apply yourself. In England and Wales a Gas Safe registered engineer notifies building control for you, and you receive a Building Regulations Compliance Certificate.

Do I need TRVs on all radiators?

In England, each heated room should have its own temperature control, usually a TRV. The exception is the room with the main thermostat, where a TRV would conflict with it.

What is weather compensation?

A sensor outside tells the boiler the outdoor temperature, and the boiler lowers the water temperature on milder days. It is one of the four extra measures a new combi can meet the rules with.

Do smart thermostats save money?

They can, but so can simpler controls. The rules treat a smart thermostat with automation and optimisation as one of four equal options for a new combi.

Are the rules different for oil boilers?

The same principles apply, with their own efficiency limits. Oil boilers are fitted by OFTEC-registered engineers, who can also self-certify the work.

Get a boiler fitted to today's rules

Tell us about your home to get a free, no-obligation quote from a Gas Safe registered engineer, with the controls and system cleaning your nation's rules require included in the price you are quoted.

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.
Compare free quotes

Free and no obligation. We only share your details with the installers we match you with.

What the rules require when a boiler is replaced

The main requirements for a replacement gas boiler in each nation's building regulations guidance, as they stood in September 2026.

boilers-replacement-rules-by-nation
Requirement England Wales Scotland Northern Ireland Minimum gas boiler efficiency 92% (ErP) 92% (ErP) 92% (ErP) 88% (SEDBUK 2009) One extra efficiency measure Combi replacements Combi replacements Every boiler replacement Not in the guidance Temperature control in each heated room Required Required TRVs in all rooms Ask building control System cleaned and flushed to BS 7593 Required Required Required Ask building control Next edition of the guidance From 24 March 2027 From 4 March 2027 Not announced Not announced
A summary, not the full rules. Your engineer applies the detail, and new editions take effect in England and Wales in March 2027.
Approved Document L (England, 2021 with 2023 amendments); Approved Document L (Wales, 2022); Domestic Building Services Compliance Guide (Scotland, 2022); Technical Booklet F1 (NI, 2022). Checked September 2026.
Compare free quotes

From vetted, accredited installers near you. Free, and no obligation.

Get free quotes
Back to top
Free, no obligation

See what a new boiler would cost

Enter your postcode and we will match you with Gas Safe registered engineers for free, no-obligation quotes.

Loading your quote form

We pass your details to one vetted local installer, so they can contact you with a quote. Our privacy policy explains how we use your data.

One short form Β· Vetted, certified installers Β· Compare quotes with no obligation