Checklist

New boiler checklist: from quote to Gas Safe certificate

From the first quote to the certificate in the post: what to check at each stage of a new boiler installation, the rules that apply where you live, and the paperwork to keep.

Last reviewed
28 September 2026
7
min read
A heating engineer fixing a carbon monoxide alarm to a utility room ceiling, with a new boiler on the wall behind
Key takeaways
  • The "Gas Safe certificate" is a Building Regulations Compliance Certificate, issued in England and Wales.
  • Your engineer must notify the work within 30 days; the certificate then arrives within about 15 working days.
  • All four nations expect a carbon monoxide alarm in the same room as a new boiler.
  • The system must be cleaned and flushed before a new boiler goes in; power flushing is one method.
  • Register the manufacturer's warranty yourself, because the appliance owner usually has to do it.

Check the engineer is Gas Safe registered, agree in writing what the job includes, and make sure the system is cleaned, the controls meet the rules and a carbon monoxide alarm is fitted. Afterwards, expect a commissioning checklist on the day and, in England and Wales, a Building Regulations Compliance Certificate in the post within a few weeks.

This checklist follows the order of a job. For what a quote costs and what is usually extra, see boiler costs; for the rules on efficiency and controls, see new boiler regulations.

Step 1: before you ask for quotes

  • Note the make, model and age of your current boiler, and where it sits.
  • Count the radiators and bathrooms, and note whether you have a hot water cylinder.
  • Decide whether you want to keep the boiler where it is: moving it adds flue and pipework.
  • Ask yourself whether a heat pump might suit your home now or later: our guide to heat pump or gas boiler helps.

Step 2: check the engineer

Only a Gas Safe registered engineer may fit a gas boiler, and it is a criminal offence to pretend to be registered. Ask to see the Gas Safe ID card: the back lists which appliances that engineer is qualified to work on.

For oil boilers, use an OFTEC-registered technician, and for solid fuel or biomass, a HETAS-registered installer. For a heat pump, the Boiler Upgrade Scheme requires an MCS-certified installer.

Step 3: what a proper quote should say

Gas Safe recommends getting the job confirmed in writing before work starts. Check the quote covers:

  • the price and exactly what it includes;
  • the boiler make and model, and the controls to be fitted;
  • how the system will be cleaned and flushed, and which inhibitor will be added;
  • the flue route and where the condensate pipe will run;
  • payment terms, the start date and how long the job will take;
  • who will notify building control, and when you will get the certificate;
  • the Gas Safe numbers of any subcontractors;
  • removal of the old boiler, and the warranties on parts and labour.

If you sign at home, you normally have 14 days to cancel, and work can only start within that time if you ask for it in writing.

Step 4: sizing, cleaning and controls

The boiler should be sized to your home's heat loss, not simply matched to the old one. Approved Document L expects a combi to be able to turn down to the typical heating load, so it does not keep switching on and off.

Before the new boiler goes in, the whole system must be cleaned and flushed, with a corrosion inhibitor added, to the British Standard BS 7593. A power flush is one way of doing this; ask which method your engineer will use and why.

The controls must meet the rules for your nation. In England and Wales a new combi also needs one extra energy-saving measure. Our guide to new boiler regulations sets out what that means.

Step 5: where the flue and the alarm go

Flue position, in millimetres

For the common fan-assisted balanced flue, Approved Document J in England sets minimum distances: 300mm from an opening such as a window, 75mm below a gutter, 200mm below the eaves and 600mm from a facing wall or boundary. A flue within reach needs a guard, and the plume of steam should not blow straight onto a neighbour's window.

A carbon monoxide alarm should go in the same room as the boiler. Approved Document J says it should be on the ceiling at least 300mm from any wall, and between 1 and 3 metres from the appliance, and should meet the standard BS EN 50291-1.

Step 6: on the day

  • The old boiler is removed and the system cleaned before the new one is fitted.
  • The flue, condensate pipe and controls are fitted where the quote said.
  • The boiler is set up and tested, and the engineer completes the Benchmark commissioning checklist.
  • The engineer shows you how to use the controls and sets the flow temperature to suit your radiators.

Step 7: the paperwork

boilers-new-boiler-paperwork

In England and Wales, your Gas Safe engineer notifies building control for you, within 30 days of the job. Gas Safe Register then posts a Building Regulations Compliance Certificate, usually within 10 to 15 working days. Keep it with the house deeds: a buyer's solicitor will ask for it.

Register the manufacturer's warranty straight away. Gas Safe notes that registration is normally done by the appliance owner, and many warranties depend on it and on an annual service.

A worked example: the dates to watch

A boiler is commissioned on Monday 2 November 2026 in England:

  • By Wednesday 2 December: the engineer must have notified the work, within 30 days.
  • By about Wednesday 23 December: the certificate should arrive, 15 working days later. If it has not, ask the engineer, and order a copy if needed.
  • If you are a landlord: the first annual gas safety check is due by 2 November 2027, with a copy of the record to your tenants within 28 days.
  • If the contract was signed at home on 5 October: you could have cancelled until the end of 19 October.

Watch out for these

  • Engineers who cannot show a Gas Safe ID card. Check the card and the back of it every time.
  • No certificate. If nothing arrives, the work may not have been notified. A missing certificate can hold up a sale or a remortgage.
  • Pressure to start before the cooling-off period ends. Work in the first 14 days should only start if you have asked for it in writing.
  • Skipped cleaning. A new boiler on a dirty system can fail early. Ask for the cleaning method in writing.
  • "Condemned" pressure on your old boiler. Only an "Immediately Dangerous" or "At Risk" notice is urgent; see when to replace your boiler.

How the rules differ across the UK

  • England and Wales: Gas Safe notifies building control and posts the compliance certificate. Carbon monoxide alarms are required with new fixed combustion appliances; in Wales the rule is wider, covering any fuel and rooms a flue passes through, since 6 January 2025.
  • Scotland: there is no Gas Safe compliance certificate. Every home with a carbon-fuelled appliance needs a carbon monoxide detector in the same room.
  • Northern Ireland: there is no Gas Safe compliance certificate either. A carbon monoxide alarm has been required with new fossil fuel appliances since 31 October 2012.
  • Rented homes: in England, landlords must fit carbon monoxide alarms in rooms with a fixed combustion appliance other than a gas cooker, and Northern Ireland has similar rules for private tenancies.
  • Gas emergencies: 0800 111 999 in Great Britain; 0800 002 001 in Northern Ireland.

Where to go next

Ready to plan your new boiler?

Tell us about your home to get a free, no-obligation quote from a Gas Safe registered engineer, then use this checklist to agree the controls, the cleaning and the paperwork before work starts.

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.
Compare free quotes

Free and no obligation. We only share your details with the installers we match you with.

Common questions

How long does a new boiler installation take?

A like-for-like swap often takes a day. Moving the boiler, changing its type or adding a cylinder takes longer, so ask for the expected duration in the quote.

Do I need a power flush with a new boiler?

The rules require the system to be cleaned and flushed before a new boiler is fitted. A power flush is one method; your engineer should explain which method suits your system.

What paperwork should I get with a new boiler?

The written quote, the Benchmark commissioning checklist, the manufacturer's warranty details and, in England and Wales, a Building Regulations Compliance Certificate from Gas Safe Register.

Does a new boiler need a carbon monoxide alarm?

Yes, in all four nations. The rules differ in detail, but in each case an alarm is expected in the same room as a new boiler.

What if my certificate never arrives?

Ask your engineer first. If the work was not notified, the job may need checking, and without the certificate you may have problems when you sell.

Ready to plan your new boiler?

Tell us about your home to get a free, no-obligation quote from a Gas Safe registered engineer, then use this checklist to agree the controls, the cleaning and the paperwork before work starts.

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.
Compare free quotes

Free and no obligation. We only share your details with the installers we match you with.

The paperwork a new boiler should come with

What you should receive, who provides it and when, so you can chase anything missing before the final payment.

boilers-new-boiler-paperwork
Document Who provides it When Written quote and job confirmation Your engineer Before work starts Benchmark commissioning checklist Your engineer On the day, at handover Building Regulations Compliance Certificate (gas) Gas Safe Register Within about 10 to 15 working days of notification, which is due within 30 days OFTEC certificate (oil) Your OFTEC-registered technician After the installation HETAS Certificate of Compliance (solid fuel and biomass) HETAS By post, within about two weeks Manufacturer warranty registration You Straight after the installation MCS certificate (heat pump or biomass) Your MCS-certified installer After the installation First gas safety record (landlords) A Gas Safe engineer Within 12 months; a copy to tenants within 28 days
The Gas Safe compliance certificate applies in England and Wales; Scotland and Northern Ireland use their own building control routes.
Gas Safe Register; Approved Documents L and J (England); Gas Safety (Installation and Use) Regulations 1998; OFTEC; HETAS; Ofgem. Checked September 2026.
Compare free quotes

From vetted, accredited installers near you. Free, and no obligation.

Get free quotes
Back to top
Free, no obligation

See what a new boiler would cost

Enter your postcode and we will match you with Gas Safe registered engineers for free, no-obligation quotes.

Loading your quote form

We pass your details to one vetted local installer, so they can contact you with a quote. Our privacy policy explains how we use your data.